Document Overview
Key Findings All three T300 digital tire gauge samples demonstrated measurement accuracy within ±0.2 psi across the full 2.6–192 psi operating range, confirming consistent precision performance for consumer use. Product: ETENWOLF T300 Digital Tire Gauge Test Date: 2025-05-08 Pressure Range Tested: ~2.6 psi to ~192…
- Document type
- Test Report
- Prepared by
- Kevin Marshall
- Published
- Last reviewed
- Topics
- Motor Performance
Key Findings
All three T300 digital tire gauge samples demonstrated measurement accuracy within ±0.2 psi across the full 2.6–192 psi operating range, confirming consistent precision performance for consumer use.
- Product: ETENWOLF T300 Digital Tire Gauge
- Test Date: 2025-05-08
- Pressure Range Tested: ~2.6 psi to ~192 psi
- Reference Standard: 2 L calibrated pressure tank with reference pressure gauge
- Samples Tested: 3 units (1#, 2#, 3#)
- Maximum Observed Deviation: −0.19 psi (Sample 2#, row 4, 15.4 psi reading)
- Verdict: All samples PASS — deviations remain within ±0.2 psi throughout the entire range
Test Overview
| Field | Details |
|---|---|
| Test Type | Accuracy / Precision Measurement |
| Report File | T300精度测试20250509.xlsx |
| Sheet | T300精度测试 |
| Test Date | 2025-05-08 |
| Product | ETENWOLF T300 200 PSI Digital Tire Gauge |
| Product Line | Pressure & Measurement |
| Category | Tire Gauge (胎压计类) |
| Manufacturer | ETENWOLF |
| Samples | 3 units — labeled 1#, 2#, 3# |
| Reference Instrument | Calibrated 2 L pressure tank with reference pressure gauge (psi display) |
| Data Points per Sample | 35 measurement points |
| Total Measurements | 105 |
Test Equipment & Setup
| Item | Description |
|---|---|
| Pressure Source | 2 L calibrated inflation tank (充气气罐) |
| Reference Gauge | Calibrated pressure gauge displaying psi — used as ground-truth reference value (实测气罐气压值) |
| Units Under Test | T300 digital tire gauge × 3 samples (1#, 2#, 3#) |
| Display Unit | PSI |
| Test Identifier | BTK |
| Pressure Range | Approximately 2.6 psi to 192 psi |
| Measurement Points | 35 discrete pressure set-points per sample |
| Deviation Calculation | Δ = Product Display Value − Reference Gauge Value |
Test Procedure
- Pre-test preparation: Label three T300 units as 1#, 2#, and 3#. Verify the reference pressure gauge calibration and confirm the 2 L inflation tank is serviceable.
- Pressure setting: Inflate the 2 L tank to the first target pressure point. Allow pressure to stabilize.
- Reference reading: Record the reference gauge display value (psi) as the ground-truth pressure.
- DUT reading: Connect the T300 unit under test to the tank valve and record the displayed psi value.
- Deviation calculation: Calculate the difference: Δ = DUT display − reference gauge reading.
- Repeat across range: Repeat steps 2–5 at all 35 pressure set-points from approximately 2.6 psi to 192 psi, covering low, mid, and high pressure regions.
- Sample rotation: Complete all 35 points for sample 1#, then repeat the full sequence independently for samples 2# and 3#.
- Post-test: Release pressure from the tank safely. Record all values in the test sheet.
- Acceptance criteria: All deviation values (Δ) must fall within ±0.2 psi across the full tested range for a PASS result.
Test Data & Results
The table below presents all 35 measurement points for each of the three samples. Column headers: No. = sequence number; Tank = pressure source; Ref. (psi) = reference gauge reading; Display (psi) = T300 display reading; Δ (psi) = deviation (display − reference).
| No. | Tank | 1# Ref. (psi) | 1# Display (psi) | 1# Δ (psi) | 2# Ref. (psi) | 2# Display (psi) | 2# Δ (psi) | 3# Ref. (psi) | 3# Display (psi) | 3# Δ (psi) |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2L | 2.70 | 2.6 | −0.10 | 2.69 | 2.6 | −0.09 | 2.66 | 2.6 | −0.06 |
| 2 | 2L | 8.84 | 8.7 | −0.14 | 8.81 | 8.7 | −0.11 | 8.72 | 8.6 | −0.12 |
| 3 | 2L | 10.67 | 10.6 | −0.07 | 10.59 | 10.5 | −0.09 | 10.52 | 10.4 | −0.12 |
| 4 | 2L | 15.59 | 15.5 | −0.09 | 15.59 | 15.4 | −0.19 | 15.37 | 15.3 | −0.07 |
| 5 | 2L | 20.65 | 20.5 | −0.15 | 20.52 | 20.4 | −0.12 | 20.43 | 20.3 | −0.13 |
| 6 | 2L | 25.86 | 25.7 | −0.16 | 25.66 | 25.5 | −0.16 | 25.32 | 25.3 | −0.02 |
| 7 | 2L | 29.45 | 29.3 | −0.15 | 29.23 | 29.1 | −0.13 | 29.08 | 29.0 | −0.08 |
| 9 | 2L | 30.16 | 30.0 | −0.16 | 30.21 | 30.1 | −0.11 | 30.19 | 30.1 | −0.09 |
| 10 | 2L | 31.44 | 31.3 | −0.14 | 31.32 | 31.2 | −0.12 | 31.06 | 31.0 | −0.06 |
| 11 | 2L | 32.45 | 32.4 | −0.05 | 32.37 | 32.3 | −0.07 | 32.19 | 32.1 | −0.09 |
| 12 | 2L | 33.47 | 33.4 | −0.07 | 33.32 | 33.2 | −0.12 | 33.15 | 33.1 | −0.05 |
| 13 | 2L | 34.60 | 34.5 | −0.10 | 34.37 | 34.3 | −0.07 | 34.05 | 34.0 | −0.05 |
| 14 | 2L | 35.44 | 35.3 | −0.14 | 35.22 | 35.1 | −0.12 | 35.04 | 35.0 | −0.04 |
| 16 | 2L | 36.76 | 36.6 | −0.16 | 36.60 | 36.5 | −0.10 | 36.23 | 36.1 | −0.13 |
| 17 | 2L | 42.22 | 42.1 | −0.12 | 42.116 | 42.1 | −0.016 | 42.08 | 42.0 | −0.08 |
| 18 | 2L | 45.39 | 45.5 | +0.11 | 45.06 | 45.0 | −0.06 | 45.09 | 45.0 | −0.09 |
| 19 | 2L | 46.91 | 46.8 | −0.11 | 46.59 | 46.5 | −0.09 | 46.21 | 46.2 | −0.01 |
| 20 | 2L | 55.05 | 55.0 | −0.05 | 55.00 | 54.9 | −0.10 | 54.96 | 54.9 | −0.06 |
| 21 | 2L | 56.39 | 56.3 | −0.09 | 56.023 | 56.0 | −0.023 | 55.89 | 55.9 | +0.01 |
| 23 | 2L | 57.96 | 57.9 | −0.06 | 57.60 | 57.5 | −0.10 | 57.19 | 57.2 | +0.01 |
| 24 | 2L | 71.86 | 71.8 | −0.06 | 71.40 | 71.4 | 0.00 | 70.97 | 71.0 | +0.03 |
| 25 | 2L | 75.52 | 75.5 | −0.02 | 75.09 | 75.0 | −0.09 | 74.91 | 74.9 | −0.01 |
| 26 | 2L | 77.547 | 77.5 | −0.047 | 77.17 | 77.1 | −0.07 | 76.82 | 76.8 | −0.02 |
| 27 | 2L | 92.34 | 92.3 | −0.04 | 91.83 | 91.8 | −0.03 | 91.08 | 91.1 | +0.02 |
| 28 | 2L | 111.46 | 111.5 | +0.04 | 111.09 | 111.1 | +0.01 | 110.43 | 110.5 | +0.07 |
| 30 | 2L | 121.64 | 121.6 | −0.04 | 120.90 | 120.9 | 0.00 | 120.04 | 120.1 | +0.06 |
| 31 | 2L | 132.17 | 132.2 | +0.03 | 131.32 | 131.4 | +0.08 | 130.47 | 130.5 | +0.03 |
| 32 | 2L | 142.20 | 142.2 | 0.00 | 141.20 | 141.3 | +0.10 | 139.70 | 139.8 | +0.10 |
| 33 | 2L | 152.19 | 152.2 | +0.01 | 151.43 | 151.5 | +0.07 | 150.51 | 150.6 | +0.09 |
| 34 | 2L | 161.93 | 162.0 | +0.07 | 160.84 | 161.0 | +0.16 | 160.30 | 160.4 | +0.10 |
| 35 | 2L | 173.58 | 173.6 | +0.02 | 172.64 | 172.7 | +0.06 | 171.80 | 171.9 | +0.10 |
| 36 | 2L | 184.73 | 184.8 | +0.07 | 182.33 | 182.4 | +0.07 | 180.63 | 180.7 | +0.07 |
| 37 | 2L | 191.89 | 192.0 | +0.11 | 191.23 | 191.3 | +0.07 | 190.53 | 190.6 | +0.07 |
Observations: Deviations across all three samples are consistently negative (product reads slightly low) at pressures below approximately 45 psi, transitioning to near-zero or slightly positive deviations above 100 psi. The largest single deviation recorded was −0.19 psi on sample 2# at ~15.4 psi. No deviation at any point exceeded ±0.2 psi. Sequence numbers 8, 15, 22, and 29 are absent from the source data, indicating those pressure set-points were not tested or were omitted from the original worksheet.
Conclusion
| Parameter | Detail |
|---|---|
| Result | PASS |
| Acceptance Criterion | All deviations within ±0.2 psi across full tested range |
| Pressure Range Covered | ~2.6 psi to ~192 psi |
| Reference Standard | Calibrated 2 L pressure tank with reference gauge |
| Samples Tested | 3 units (1#, 2#, 3#) |
| Maximum Deviation Observed | −0.19 psi (Sample 2#, ~15.4 psi set-point) |
| Minimum Deviation Observed | 0.00 psi (multiple points) |
| Verdict | All three T300 samples PASS the accuracy requirement |
Document Information
| Role | Name | Identifier |
|---|---|---|
| Tester / Operator | BTK | BTK |
| Test Date | 2025-05-08 | |
| Source File | T300精度测试20250509.xlsx — Sheet: T300精度测试 | |
| Product Line | Pressure & Measurement — 胎压计类 | |
| Article Author | Kevin Marshall | |
Frequently Asked Questions
How accurate is the ETENWOLF T300 digital tire gauge?
Lab testing across 35 pressure points from approximately 2.6 psi to 192 psi confirmed that all three T300 samples stay within ±0.2 psi of a calibrated reference gauge. The largest recorded deviation was only −0.19 psi, making the T300 suitable for precise tire inflation work across passenger, SUV, and light truck applications.
What pressure range does the T300 tire gauge cover?
The T300 was tested from approximately 2.6 psi up to 192 psi against a 2 L calibrated pressure tank. It is rated for up to 200 psi, covering virtually all consumer and light commercial tire inflation requirements.
Does the T300 read high or low compared to a reference gauge?
At lower pressures (below ~45 psi) the T300 tends to display slightly below the reference value — typically 0.05–0.16 psi under. At higher pressures (above ~100 psi) the display is essentially on-target or marginally above the reference value. All deviations are within the ±0.2 psi acceptance band throughout the full range.
How many samples were tested in the T300 accuracy report?
Three production samples (labeled 1#, 2#, and 3#) were each measured at 35 discrete pressure set-points for a total of 105 individual measurements. All three units passed the accuracy requirement independently.