RoHS Compliance Test Report – ETENWOLF T200 Tire Pressure Detector (Report No. WTH25X07183016C)

Document Overview

Document Overview This page presents the structured knowledge base article for RoHS Test Report WTH25X07183016C, issued by Waltek Testing Group (Shenzhen) Co., Ltd. on 2025-07-25. The report covers restricted substance screening of the ETENWOLF T200 Tire Pressure Detector in accordance with EU RoHS Directive 2011/65/EU…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
Pressure & Measurement

Document Overview

This page presents the structured knowledge base article for RoHS Test Report WTH25X07183016C, issued by Waltek Testing Group (Shenzhen) Co., Ltd. on 2025-07-25. The report covers restricted substance screening of the ETENWOLF T200 Tire Pressure Detector in accordance with EU RoHS Directive 2011/65/EU and its amendment (EU) No. 2015/863. The scope of testing encompasses 10 restricted substances across 30 individual component parts of the submitted sample, using a combination of XRF screening and confirmatory chemical analysis methods. The overall test conclusion is PASS.

Field Detail
Report Number WTH25X07183016C
Issuing Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Date of Issue 2025-07-25
Testing Period 2025-07-13 to 2025-07-18
Date of Sample Receipt 2025-07-13
Directive Covered RoHS 2011/65/EU and amendment (EU) 2015/863
Test Conclusion PASS

Product Information

The tested product is the ETENWOLF T200 Tire Pressure Detector, a compact electronic device designed for measuring and monitoring tire pressure. The applicant and manufacturer is Guangdong Bestek Technology Co., LTD, located at No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China.

Field Detail
Sample Name Tire Pressure Detector
Model Number T200
Reference Model Number NA
Brand NA (filed under applicant)
Applicant Guangdong Bestek Technology Co., LTD
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China

The T200 is constructed from a combination of plastic housings, metal structural components, PCB assemblies, SMD electronic components, rubber seals, and LED elements — all of which were individually assessed for restricted substance content under this report.

Key Details

A total of 30 component parts were subjected to XRF screening, with confirmatory chemical testing performed where XRF results fell within the inconclusive (IN) range. The table below summarises the test results for Lead (Pb), Cadmium (Cd), Mercury (Hg), Chromium (Cr/Cr6+), Bromine (Br), PBBs, and PBDEs across all tested parts.

No. Part Description Pb Cd Hg Cr Br Chemical Confirmation
1 Black plastic shell BL BL BL BL BL NA
2 Black plastic BL BL BL BL BL NA
3 Black w/transparent plastic sheet BL BL BL BL BL NA
4 Silvery metal sheet BL BL BL BL NA NA
5 Silvery metal spring BL BL BL BL NA NA
6 Silvery metal screw BL BL BL BL NA NA
7 Silvery metal screw BL BL BL BL NA NA
8 Black plastic film BL BL BL BL BL NA
9 White plastic BL BL BL BL BL NA
10 Silvery metal body BL BL BL BL NA NA
11 Silvery square metal body (switch) BL BL BL BL NA NA
12 Black plastic button (switch) BL BL BL BL BL NA
13 Silvery metal sheet (switch) BL BL BL IN NA Cr6+: Negative
14 Black plastic base (switch) BL BL BL BL BL NA
15 Silvery metal PIN (switch) BL BL BL BL NA NA
16 Transparent LED body BL BL BL BL BL NA
17 Silvery metal PIN BL BL BL BL NA NA
18 Black triode SMD BL BL BL BL BL NA
19 Black cladding PCB board (tested as a whole) BL BL BL BL IN PBBs: ND; PBDEs: ND
20 Brown capacitor SMD BL BL BL BL BL NA
21 Gray solid material (Inductance) BL BL BL BL BL NA
22 Coppery metal coil (Inductance) BL BL BL BL NA NA
23 Black IC SMD BL BL BL BL BL NA
24 Black resistance SMD BL BL BL BL BL NA
25 Black IC SMD BL BL BL BL BL NA
26 Yellow LED BL BL BL BL BL NA
27 Solder BL BL BL BL NA NA
28 Black plastic BL BL BL BL BL NA
29 Black rubber tube BL BL BL BL BL NA
30 Black rubber ring BL BL BL BL BL NA

Key: BL = Below Limit | IN = Inconclusive (further chemical testing performed) | NA = Not Applicable | ND = Not Detected

Two parts required confirmatory chemical testing: Part 13 (Silvery metal sheet – switch) returned a Cr6+ Negative result via boiling water extraction per IEC 62321-7-1:2015, and Part 19 (Black cladding PCB board) returned ND for both PBBs and PBDEs via GC-MS per IEC 62321-6:2015. All results confirm compliance.

The RoHS restricted substance limits applied in this report are as follows:

Restricted Substance Maximum Permitted Limit
Cadmium (Cd) 0.01% (100 mg/kg)
Lead (Pb) 0.1% (1000 mg/kg)
Mercury (Hg) 0.1% (1000 mg/kg)
Hexavalent Chromium (Cr6+) 0.1% (1000 mg/kg)
Polybrominated Biphenyls (PBBs) 0.1% (1000 mg/kg)
Polybrominated Diphenyl Ethers (PBDEs) 0.1% (1000 mg/kg)

Standards & Compliance

The T200 was tested against the following directives and analytical standards:

Standard / Directive Scope
EU RoHS Directive 2011/65/EU Restriction of Hazardous Substances in electrical and electronic equipment
Amendment (EU) No. 2015/863 Adds four phthalates (DEHP, BBP, DBP, DIBP) to the restricted substances list
IEC 62321-3-1:2013 XRF screening for Pb, Hg, Cd, total Cr, total Br
IEC 62321-4:2013+AMD1:2017 CSV Mercury (Hg) analysis by ICP-OES
IEC 62321-5:2013 Lead (Pb) and Cadmium (Cd) analysis by ICP-OES
IEC 62321-7-1:2015 Hexavalent Chromium (Cr6+) in metals by boiling water extraction
IEC 62321-7-2:2017 Hexavalent Chromium (Cr6+) in polymers and electronics by colorimetric method (UV-Vis)
IEC 62321-6:2015 PBBs and PBDEs analysis by GC-MS
IEC 62321-8:2017 Phthalates (DEHP, BBP, DBP, DIBP) analysis by GC-MS

Method Detection Limits (MDL) applied during chemical testing:

Test Item MDL
Pb 10 mg/kg
Cd 10 mg/kg
Hg 10 mg/kg
Cr6+ (polymer/composite) 10 mg/kg
Cr6+ (metal) 0.1 μg/cm²
PBBs (single compound) 10 mg/kg
PBDEs (single compound) 10 mg/kg

Validity & Certification Body

This test report was issued on 2025-07-25 and covers the sample as tested during the period 2025-07-13 to 2025-07-18. The report is specific to the submitted sample batch; results represent the condition of the sample at the time of testing. Note that storage conditions and production date of the tested sample were unavailable, which is particularly relevant to the Cr6+ result interpretation.

Field Detail
Report Number WTH25X07183016C
Date of Issue 2025-07-25
Testing Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Laboratory Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao’an District, Shenzhen, Guangdong, China
Laboratory Website http://www.waltek.com.cn
Contact Telephone +86-755-33663308
Contact Fax +86-755-33663309
Contact Email [email protected]
Signed By Hugo Chen, on behalf of Waltek Testing Group (Shenzhen) Co., Ltd.

Waltek Testing Group is an internationally recognised third-party testing and certification laboratory. This report was prepared and signed by authorised personnel in accordance with the laboratory’s quality management procedures.

Frequently Asked Questions

What does the RoHS PASS result mean for the ETENWOLF T200?

It means that all 30 tested components of the T200 Tire Pressure Detector were found to contain restricted hazardous substances — including Lead, Cadmium, Mercury, Hexavalent Chromium, PBBs, and PBDEs — at levels below the maximum thresholds set by EU RoHS Directive 2011/65/EU and its amendment (EU) 2015/863. The product is compliant for sale in the European Union and other markets that recognise RoHS compliance.

Why were two parts flagged as inconclusive (IN) during XRF screening?

Part 13 (Silvery metal sheet – switch) returned an inconclusive Chromium reading by XRF, and Part 19 (Black cladding PCB board) returned an inconclusive Bromine reading. Per IEC 62321-3-1:2013, an IN result does not indicate a failure — it triggers confirmatory chemical testing. Both parts subsequently passed: Cr6+ was confirmed Negative for Part 13, and PBBs and PBDEs were Not Detected for Part 19.

Which phthalates were included in the scope of this report?

The report scope includes phthalates as required by amendment (EU) 2015/863: DEHP (bis(2-ethylhexyl) phthalate), BBP (benzyl butyl phthalate), DBP (dibutyl phthalate), and DIBP (diisobutyl phthalate). These were analysed by GC-MS in accordance with IEC 62321-8:2017. The full phthalate results appear in the complete report pages not reproduced here.

How long is this RoHS test report valid?

RoHS test reports do not carry a fixed expiry date in the same way that product certifications do. However, the results are specific to the submitted sample batch as tested between 2025-07-13 and 2025-07-18. If the product design, materials, or supply chain changes, a new test report should be obtained to maintain compliance documentation. For ongoing market access, manufacturers typically refresh RoHS reports when significant product or component changes occur.

Related Documents

The following certification and compliance documents are commonly associated with electronic measurement devices such as the T200 Tire Pressure Detector. Obtaining the full suite of certifications supports market access across key global regions:

  • CE Declaration of Conformity — Required for EU market access; covers electromagnetic compatibility (EMC), low voltage, and RoHS compliance under the CE marking framework.
  • FCC Declaration of Conformity / FCC ID Certification — Required for the United States market; covers radio frequency emissions and interference for electronic devices.
  • REACH SVHC Declaration — Complements RoHS by addressing Substances of Very High Concern under EU REACH Regulation (EC) No. 1907/2006.
  • KC Certification (Korea) — Required for electronic products sold in South Korea, covering safety and EMC requirements under the Radio Waves Act and Electrical Appliances Safety Act.
  • UN 38.3 Test Report — If the T200 includes or is shipped with a lithium battery, a UN 38.3 transport test report is required for air freight compliance.
  • ISO 9001 Quality Management Certification — Manufacturer quality system certification providing assurance of consistent production standards.
  • EMC Test Report (EN 55032 / CISPR 32) — Electromagnetic emissions testing typically required as part of CE marking for electronic measurement equipment.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16