CE-EMC Test Report WTH25H07183005E — T300/T300PLUS Electronic Tire Pressure Gauge

Document Overview

Document Overview This page presents the CE Electromagnetic Compatibility (EMC) Test Report issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. for the electronic tire pressure gauge models T300 and T300PLUS. The report covers conducted emissions, radiated emissions, and harmonic/flicker measurements in accordance with the…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
Pressure & Measurement

Document Overview

This page presents the CE Electromagnetic Compatibility (EMC) Test Report issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. for the electronic tire pressure gauge models T300 and T300PLUS. The report covers conducted emissions, radiated emissions, and harmonic/flicker measurements in accordance with the applicable European harmonised standards for electrical measurement and control equipment.

Field Detail
Report Reference Number WTH25H07183005E
Document Type CE-EMC Test Report
Test Report Form Number TRF EN IEC 61326-1:2021-EMC-001-V01
Internal Form Reference HCT/RF-23-21
Issuing Laboratory Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Date of Issue 2025-07-17
Test Period 2025-07-15 to 2025-07-17
Sample Receipt Date 2025-07-10
Overall Test Result Pass

Product Information

The Equipment Under Test (EUT) is an electronic tire pressure gauge designed and manufactured by Guangdong Bestek Technology Co., Ltd. It is marketed globally under the ETENWOLF brand. The T300 and T300PLUS models are portable, battery-operated inflation tools intended for consumer and professional automotive use, capable of measuring and displaying tire pressure with digital accuracy.

Attribute Value
Product Name Electronic Tire Pressure Gauge
Model Numbers T300 / T300PLUS
Applicant Guangdong Bestek Technology Co., LTD
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Brand ETENWOLF
Product Category Electrical measurement and control equipment

Key Details

The test report covers three major EMC test areas as required under the applicable CE directives. The following table summarises the scope of each test section as documented in the report’s table of contents and header information.

Test Section Standard Applied Test Focus Result
Disturbance Voltage at Mains Terminals (Conducted Emissions) EN IEC 61326-1:2021 Measurement of conducted radio-frequency disturbance voltage on power supply lines Pass
Harmonic Current Emissions EN IEC 61000-3-2:2019+A1:2021 Limits for harmonic current emissions for equipment with input current up to and including 16 A per phase Pass
Voltage Fluctuations and Flicker EN 61000-3-3:2013+A2:2021 Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems Pass

The report spans 44 pages in total, including detailed measurement data, instrument calibration records, test configuration diagrams, and decision rule applications. All measurements were conducted within the laboratory’s accredited scope under controlled conditions.

Standards & Compliance

The T300/T300PLUS was evaluated against the following harmonised European standards, which support the CE marking declaration for the EMC Directive 2014/30/EU:

Standard Title Relevance
EN IEC 61326-1:2021 Electrical equipment for measurement, control and laboratory use — EMC requirements — Part 1: General requirements Primary EMC standard for the product category; covers both emissions and immunity
EN IEC 61000-3-2:2019+A1:2021 Electromagnetic compatibility — Limits for harmonic current emissions Controls harmonic distortion injected into the mains supply
EN 61000-3-3:2013+A2:2021 Electromagnetic compatibility — Limitation of voltage changes, voltage fluctuations and flicker Ensures the product does not cause perceptible flicker on the public supply network

Compliance with these standards demonstrates that the T300/T300PLUS meets the essential requirements of the EU EMC Directive and is eligible to bear the CE mark for sale throughout the European Economic Area. The test report form used (TRF EN IEC 61326-1:2021-EMC-001-V01) is the standardised template for this product class.

Validity & Certification Body

This test report was prepared and approved by accredited engineers at Waltek Testing Group HCT (Shenzhen) Co., Ltd., a recognised third-party testing laboratory. The report was prepared by Snow Zeng and approved by Tony Wu.

Field Detail
Laboratory Name Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Laboratory Address Building B, Tianji Industrial Park, 1/F, 2/F & 3/F, No. 30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
Telephone 0755-84616666
Service Hotline 400-0066-989
Email [email protected]
Report Reference WTH25H07183005E
Date of Issue 2025-07-17
Prepared By Snow Zeng
Approved By Tony Wu
Report Validity Valid for the tested product configuration as described in the report; subject to re-testing upon design change

Frequently Asked Questions

What does CE-EMC certification mean for the T300/T300PLUS tire pressure gauge?

CE-EMC certification means the T300/T300PLUS has been independently tested and found to comply with EU Directive 2014/30/EU on electromagnetic compatibility. This confirms that the device neither emits electromagnetic disturbances above permitted limits nor is susceptible to interference in ways that would impair its operation. The CE mark allows the product to be legally placed on the market across all European Economic Area member states.

Which specific standards were tested in report WTH25H07183005E?

Report WTH25H07183005E covers three standards: EN IEC 61326-1:2021 (general EMC requirements for measurement and control equipment), EN IEC 61000-3-2:2019+A1:2021 (harmonic current emission limits), and EN 61000-3-3:2013+A2:2021 (voltage fluctuation and flicker limits). All three tests returned a Pass result.

Who conducted the EMC tests for the T300/T300PLUS?

The tests were conducted by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party testing laboratory based in Shenzhen, Guangdong, China. The report was prepared by Snow Zeng and approved by Tony Wu. Testing took place between 2025-07-15 and 2025-07-17, with the report issued on 2025-07-17.

Does this EMC report cover both T300 and T300PLUS models?

Yes. Report WTH25H07183005E explicitly lists both the T300 and T300PLUS as the model numbers under test. Both variants of the electronic tire pressure gauge are covered by the same test findings and Pass result recorded in this document.

Related Documents

For a complete regulatory compliance picture of the T300/T300PLUS electronic tire pressure gauge, the following additional certification and test report types are typically required or recommended alongside this CE-EMC report:

  • CE-LVD Test Report — Low Voltage Directive (2014/35/EU) safety testing to EN IEC 62368-1 or equivalent, covering electrical safety and protection against shock and fire hazard.
  • CE-RED Test Report — Radio Equipment Directive (2014/53/EU) assessment if the device incorporates any wireless communication module (e.g., Bluetooth for pressure data transmission).
  • UN 38.3 Battery Transport Test Report — Mandatory for products containing lithium-ion or lithium-polymer batteries to comply with international transport regulations.
  • RoHS Compliance Report — Confirmation that the product meets EU RoHS Directive 2011/65/EU restrictions on hazardous substances including lead, mercury, cadmium, and certain brominated flame retardants.
  • REACH SVHC Declaration — Substance of Very High Concern screening report under the REACH Regulation (EC) No 1907/2006.
  • FCC Part 15B Declaration of Conformity — Required for market entry in the United States, covering unintentional radiator emissions for digital devices.
  • KC Certification — Korean Certification mark required for electrical and electronic products sold in the Republic of Korea.
  • EU Declaration of Conformity (DoC) — The manufacturer’s formal declaration referencing all applicable directives and harmonised standards, signed by an authorised representative.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30
Document Page 31
Document Page 32
Document Page 33
Document Page 34
Document Page 35
Document Page 36
Document Page 37
Document Page 38
Document Page 39
Document Page 40
Document Page 41
Document Page 42
Document Page 43
Document Page 44